5-26 Calibration and Adjustment
3. Double click on the station that you want to configure.
 The Heater Control Loop Parameters Window opens (Figure 5-29).
Figure 5-29 Heater Control Loop Parameters Window - Main Tab
4. Enter the desired settings on the Main tab.
5. If you want to set ramp and standby options, go to Step 6, otherwise skip to Step 9.
6. Click on the Controlled Process States tab (Figure 5-30).
7. Enter the desired ramp temperature, airflow, and time.
 The ramp temperature is generally higher than the dispense station temperature and is
used to quickly heat a part in the pre-dispense station.
8. Enter the desired standby temperature, airflow, and time.
 The standby temperature is generally lower than the dispense station temperature and is
used to reduce energy when a board is not received for a specified amount of time.
9. Click on
OK to close the Heater Control Window.
10. Click on
Main to return to the Fluidmove Main Window.