82
"A" Group: Standard Functions Section 3-5
A044 V/f characteristic curve Four available V/f curves;
00... Constant torque
01... Reduced torque (1.7)
02... Free V/F
03... Sensorless vector (SLV)
8 00 –
A244 V/f characteristic curve,
2
nd
motor
8 00 –
A045 V/f gain Sets voltage gain of the inverter,
range is 20. to 100.%
9 100. %
A245 V/f gain, 2
nd
motor 9 100. %
a046 Voltage compensation gain for
automatic torque boost
Sets voltage compensation gain
under automatic torque boost,
range is 0. to 255.
9 100. –
a246 Voltage compensation gain for
automatic torque boost,
2
nd
motor
9 100. –
a047 Slip compensation gain for
automatic torque boost
Sets slip compensation gain
under automatic torque boost,
range is 0. to 255.
9 100. –
a247 Slip compensation gain for
automatic torque boost,
2
nd
motor
9 100. –
"A" Function Run
Mode
Edit
Defaults
Func.
Code
Name Description EU Units