77
"A" Group: Standard Functions Section 3-5
(motor running). If it is necessary to check the value of F001 during Run Mode,
please monitor
D001 instead of F001.
There are two ways to program the speeds into the registers
A020 to A035:
1. Standard keypad programming
2. Programming using the CF switches. Set the speed following these steps:
a) Turn the Run command OFF (Stop Mode).
b) Turn inputs ON to select desired Multi-speed. Display the value of
F001
on the digital operator.
c) Set the desired output frequency by pressing the and keys.
d) Press the key once to store the set frequency. When this occurs,
F001 indicates the output frequency of Multi-speed n.
e) Press the key once to confirm that the indication is the same as
the set frequency.
f) Repeat operations in 2. a) to 2. e) to set the frequency of other Multi-
speeds.
Digital Input configuration for bit operation
Jog Frequency - The jog speed setting is used whenever the Jog command
is active. The jog speed setting range is arbitrarily limited to 9.99 Hz, to pro-
vide safety during manual operation. The acceleration to the jog frequency is
Option
Code
Terminal
Symbol
Function
Name
State Description
32~38 SF1~SF2 Multistage
Speed ~ Bit
Operation
ON Makes multistage speed by combi-
nation of the inputs.
OFF
Valid for inputs: C001~C007
Required settings: F001, A001=02, A020 to A035
Notes:
• When programming the multi-speed settings, be sure to press the key each
time and then set the next multi-speed setting. Note that when the key is not
pressed, no data will be set.
• When a multi-speed setting more than 50Hz (60 Hz) is to be set, it is necessary to
program the maximum frequency A004 high enough to allow that speed