EasyManua.ls Logo

Omron MX2 - Logic Output Function Info

Omron MX2
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
217
Using Intelligent Output Terminals Section 4-6
4-6-22 Logic Output Function
The inverter has a built-in logic output feature. Select any two operands out of
all intelligent output options except LOG1~LOG3 and their operator out of
AND, OR, or XOR (exclusive OR). The terminal symbol for the new output is
[LOG]. Use
C021, C022 or C026 to route the logical result to terminal [11], [12] or
the relay terminals.
Option
Code
Terminal
Symbol
Function
Name
State Description
33
34
35
LOG1
LOG2
LOG3
Logic
Output
Function
ON when the Boolean operation
specified by C144 /C145/C147
has a logical "1" result
OFF when the Boolean operation
specified by C144 /C145/C147 has a
logical "0" result
Valid for inputs: 11, 12, AL0 - AL2
Required settings: C141~C150
Intelligent outputs used as
internal inputs:
RUN, FA1, FA2… or
all other output
signals
Operand A
RUN, FA1, FA2… or
all other output
signals
Operand B
Operator
AND, OR, XOR
[LOG1]/[LOG2]/[LOG3]
(C144/C147/C150)
C142/C145/C148
C143/C146/C149
Input
Status
[LOG] Output
State
A B AND OR XOR
00000
01011
10011
11110