176
Using Intelligent Input Terminals Section 4-5
The two diagrams below input wiring circuits using the inverter's internal
+24 V supply. Each diagram shows the connection for simple switches, or for
a field device with transistor outputs. Note that in the lower diagram, it is nec-
essary to connect terminal [L] only when using the field device with transis-
tors. Be sure to use the correct connection of the short bar shown for each
wiring diagram.
Sinking Inputs, Internal Supply
Short bar = [PLC] – [P24] position
GND
7
1
Field device
Open collector outputs,
NPN transistors
MX2
P24
1
7
24 V
PLC
Input
circuits
+
-
Logic GND
Input common
Short bar
Input switches
L
Sourcing Inputs, Internal Supply
Short bar = [PLC] – [L] position
Common to
[P24]
7
1
Field device
PNP transistor
sousing outputs
MX2
P24
1
7
24 V
PLC
Input
circuits
+