091
Free setting V/f frequency 7 > Frequency upper limit (A061)
092
Free setting V/f frequency 7 > Frequency lower limit (A062)
095
Free setting V/f frequency 7 > Output Frequency setting (F001)
Multi-speed freq. 0 (A020)
201
Frequency upper limit (A261) > Max. Frequency (A204)
202
Frequency lower limit (A262) > Max. Frequency (A204)
205
Output Frequency setting (F001)
Multi-speed freq. 0 (A220)
> Max. Frequency (A204)
215
Output Frequency setting (F001)
Multi-speed freq. 0 (A220)
> Frequency upper limit (A261)
225
Frequency lower limit (A262) > Output Frequency setting (F001)
Multi-speed freq. 0 (A220)
231
Start frequency (A082) > Frequency upper limit (A261)
232
Start frequency (A082) > Frequency lower limit (A262)
235
Start frequency (A082) > Output Frequency setting (F001)
Multi-speed freq. 0 (A220)
285
Output Frequency setting (F001)
Multi-speed freq. 0 (A220)
= Jump frequency (A063/A063/
A063±A064/A066/A068)
291
Free setting V/f frequency 7 > Frequency upper limit (A261)
292
Free setting V/f frequency 7 > Frequency lower limit (A262)
295
Free setting V/f frequency 7 > Output Frequency setting (F001)
Multi-speed freq. 0 (A220)
Warning
code
Warning conditions
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

Table of Contents

Other manuals for Omron MX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 and is the answer not in the manual?

Omron MX2 Specifications

General IconGeneral
ModelMX2
CategoryInverter
Enclosure RatingIP20
Control MethodV/f control, Sensorless vector control
Frequency Range0.1 to 400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Short circuit
CommunicationModbus RTU
Ambient Temperature-10 to 50 °C (without freezing or condensation)
Overload Capacity150% for 60 seconds
Cooling MethodFan Cooled
Humidity5 to 95% RH (without condensation)
AltitudeUp to 1000m without derating
Voltage200-240 VAC, 380-480 VAC
Braking UnitBuilt-in (for certain models), Optional External