– 87 – NWA-008845-001 Rev.5.0
32ch1002.fm
DESCRIPTION DATA
Specify the maximum number of digits for
Authorization Code with MP.
(1)
(2)
11
Maximum number of digits
01-16 : 1 digit-16 digits
NONE : 10 digits
Assign the ID Code Development number for
Authorization Code.
(1)
(2)
Y=A0
0: Authorization Code
0-9: ID Code Development No. 00-09
NOTE: CM2A Y=00-09 is determined by this
data.
Assign the ID Code for Authorization Code.
(1)
(2)
Y=00-09 ID Code Development No. 00-09
X-XX...XX (Maximum16 digits):
ID Code for Authorization Code
0000-2999: ID Code Pattern No.
Assign the purpose of ID Code.
(1)
(2)
Y=10
0000-2999: ID Code Pattern No.
0 : Validate the ID Code entered from sta-
tions and trunks
1 : Validate the ID Code entered from sta-
tions
3 : Invalidate the ID Code entered from
stations and trunks
Assign the desired Trunk Restriction Class for
each ID Code Pattern number.
(1)
(2)
Y=11
0000-2999: ID Code Pattern No.
1 : Unrestricted (RCA)
2 : Non-Restricted-1 (RCB)
3 : Non-Restricted-2 (RCC)
4 : Semi-Restricted-1 (RCD)
5 : Semi-Restricted-2 (RCE)
6 : Restricted-1 (RCF)
7 : Restricted-2 (RCG)
8 : Fully-Restricted (RCH)
A
CM42
CM2A
B
JUNE/01/2007
AUTHORIZATION CODE