– 127 – NWA-008845-001 Rev.5.0
32ch1002.fm
AUTOMATIC RECALL
PROGRAMMING
DESCRIPTION DATA
Specify the timing for AUTOMATIC RE-
CALL.
If no data is set, the following timing will be
applied:
Attendant Recall : 31.2-33.6 seconds
Non Exclusive Hold : 60-64 seconds
Exclusive Hold : 236-240 seconds
Transfer Recall : 24-28 seconds
Attendant Hold Recall: 31.2-33.6 seconds
Camp-On Recall : 24-32 seconds
•
(1)
(2)
Y=0
00: Attendant Recall
01-14: 2.4-33.6 seconds
(2.4 second increments)
15-24: 38.4-124.8 seconds
(9.6 second increments)
(1)
(2)
05: Non Exclusive Hold
01-98: 4-392 seconds
(4 second increments)
99 : Recall is not performed
(1)
(2)
06: Exclusive Hold
01-98: 4-392 seconds
(4 second increments)
99 : Recall is not performed
(1)
(2)
07: Transfer Recall
01-30: 4-120 seconds
(4 second increments)
(1)
(2)
11: Attendant Hold Recall
01-14: 2.4-33.6 seconds
(2.4 second increments)
15-24: 38.4-124.8 seconds
(9.6 second increments)
(1)
(2)
26: Camp-On Recall
01-15: 16-128 seconds
(8 second increments)
START
CM41
END
AUTOMATIC RECALL