INTRODUCTION
– 11 – NWA-008845-001 Rev.5.0
32ch0001.fm
CONDITIONS ON CARD/TERMINAL NUMBER ASSIGNMENT
BY CM14
In the Series 3200 R6.2 or later software, the card/terminal number can be assigned by CM14 same as
CM10. But, you must consider the following conditions on the card/terminal number assignment.
(1) Card Number of AMP Trunk (PN-2AMP) <C100-C163>
(a) The card number should be assigned to the FP No. 00-03 as follows.
For FP No. 00: C100-C115
For FP No. 01: C116-C131
For FP No. 02: C132-C147
For FP No. 03: C148-C163
(b) Do not assign the card number to the other FP No. than above (a).
(c) This data is not effective for a remote site of Remote PIM over IP system.
(2) DSS Console number <E100-E131>
(a) For the FP No. 00-03, the DSS Console number should be assigned as follows.
[Series 3400 R9.1 software or before]
For FP No. 00: E100-E107
For FP No. 01: E108-E115
For FP No. 02: E116-E123
For FP No. 03: E124-E131
(b) For the FP No. 00-03 of MP built-in FP/FP card of Main Site and MP built-in FP of Remote Site,
the DSS Console number (E100-E131) can be assigned without limit as shown above (a).
[Series 3500 software or later]
(c) For the other FP No. than above (a), the DSS Console number (E100-E131) can be assigned
without limit as shown above (a).
(d) This data is effective for a remote site of Remote PIM over IP system.
(e) The same number (the last two digits of the data) should not be used for both DSS Console
number (E100-E131) and Add-On Module number (EC00-EC31).