– 89 – NWA-008845-001 Rev.5.0
32ch1002.fm
AUTOMATED ATTENDANT
PROGRAMMING
DESCRIPTION DATA
Assign the data for Automated Attendant to the
required trunks.
•
•
•
•
(1)
(2)
Y=02 Terminating System in Day Mode
Y=03 Terminating System in Night Mode
Y=40 Terminating System in Mode A
Y=41 Terminating System in Mode B
000-255: Trunk No.
09: Automated Attendant
NOTE: When providing a Night Message
for Automated Attendant, the 2nd
Answering Message which is
assigned by CM49 Y=00 2nd data
02XX is used for the Night Message.
In that case, the 2nd data 08 of
CM30 Y=30, 31 cannot be specified
for handling of Busy/Not Available
Automated Attendant destination.
•
•
(1)
(2)
Y=30 Handling of busy/not available Auto-
mated Attendant destination in Day Mode
Y=31 Handling of busy/not available Auto-
mated Attendant destination in Night Mode
000-255: Trunk No.
00 : C.O. line release
01 : Forwarded to TAS indicator
03 : Forwarded to Attendant Console
04 : Forwarded to DIT Station
05 : Music and DT connection for Redial
06 : DT connection for redial
08 : 2nd Answering Message + DT
connection for redial NOTE
15 : C.O. line release
•
•
(1)
(2)
Y=32 Handling of timed-out Automated
Attendant call in Day Mode
Y=37 Handling of timed-out Automated
Attendant call in Night Mode
000-255: Trunk No.
00 : C.O. line release
01 : Forwarded to TAS indicator
03 : Forwarded to Attendant Console
04 : Forwarded to DIT station
06 : DT connection for redial
15 : C.O. line release
START
CM30
A
AUTOMATED ATTENDANT