– 665 – NWA-008845-001 Rev.5.0
32ch1010.fm
STATION SPEED DIALING
(1) To provide Single Line Telephone or D
term
:
DESCRIPTION DATA
Assign Service Restriction Class A to each sta-
tion.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow Station Speed Dialing in the Service Re-
striction Class A assigned by CM12 Y=02.
(1)
(2)
Y=07
00-15: Service Restriction Class A
1 : Allow
Assign access codes for Station Speed Dialing,
Origination, Entry and Cancel, respectively.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code (#*, 7*, 7#)
A064: Origination
A065: Entry
A066: Cancel
Specify whether to provide Toll Restriction for
an outgoing call by Station Speed Dialing.
(1)
(2)
035
0: Not provided
1: To provide
Specify whether to set “#” dialing as paused
data (1.5 seconds) or called number to C.O.
line when DTMF station or D
term
dials “#” in
the setting of Station Speed Dialing feature.
(1)
(2)
168
0 : Paused data (1.5 seconds)
1 : Dialed digit
Specify “*” dialing is set as programmable
pause by CM41 Y=0>38 or dialed digit when
the DTMF station or D
term
dials “*” in the set-
ting of the Station Speed Dialing feature.
(1)
(2)
171
0 : Programmable pause by CM41
Y=0>38
1:Dialed digit
Assign the Programmable pause of Station
Speed Dialing.
(1)
(2)
Y=0
38
00-07: 1.5-12 seconds
(1.5 second increments)
If no data is set, the default setting is 1.5
seconds.
START