EasyManua.ls Logo

Philips Sopho 2000 IPS - Centrex Compatibility

Philips Sopho 2000 IPS
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 198 – NWA-008845-001 Rev.5.0
32ch1003.fm
CENTREX COMPATIBILITY
PROGRAMMING
In addition to the programming of DIRECT OUTWARD DIALING (DOD) Page 322, do the fol-
lowing programming.
DESCRIPTION DATA
Assign the Centrex Trunk function to the
required trunk routes.
(1)
(2)
Y=86
00-63: Trunk Route No.
0: Centrex Trunk
Provide the capability for sending a hookflash
signal to the Centrex.
(1)
(2)
Y=16
00-63: Trunk Route No.
1: Sending
Assign the access code for sending a hookflash
signal to the Centrex Line from a PB Single-
Line Telephone.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A158
Assign the Centrex Trunk as a Prime Line to
the desired D
term
extension.
(1)
(2)
X-XXXXXXXX: My Line No.
D000-D255: Trunk No.
START
CM35
CM20
CM93
END
CENTREX COMPATIBILITY