– 354 – NWA-008845-001 Rev.5.0
32ch1006.fm
ENHANCED 911
PROGRAMMING
DESCRIPTION DATA
Assign an AP number to the 911 Sender trunk.
The AP number is given by the SENSE switch
on the 911 Sender trunk.
(1)
(2)
Y=0
04-15, 20-31: AP No.
08: 911 Sender Trunk (4RSTB card)
Assign 911 Sender trunk number to each 911
Sender trunk.
(1)
(2)
Y=04
00-15: 911 Sender Trunk No.
XX Z
XX: 04-15, 20-31: AP No. assigned by
CM05
Z : 0-3: Circuit No.
Send ANI signal to the network on Enhanced
911.
(1)
(2)
474: Enhanced 911
0: To send
Specify whether the Sender Tone will be sent
when a call originated, or not.
(1)
(2)
475: Sending of Sender Tone
0 : Not sent (No tone)
1: To send
Provide the System with Enhanced 911. (1)
(2)
52: Enhanced 911
0: To provide
Specify that all circuits on the 911 Sender
trunk are used as sender.
NOTE: The AP number 0-3 corresponds to
the AP numbers assigned by CM05
(04-15, 20-31) as shown below:
CM31 Y=2
CM05 Y=0
AP Number 0: AP Number X
AP Number 1: AP Number Y
AP Number 2: AP Number Z
AP Number 3: AP Number W
(X<Y<Z<W)
(1)
(2)
Y=2
0-3: AP No. NOTE
0: All circuits are used as the 911 Sender
START
CM05
INITIAL
CM06
INITIAL
CM08
CM09
INITIAL
CM31
INITIAL
A
ENHANCED 911