– 720 – NWA-008845-001 Rev.5.0
32ch1011.fm
UNIFORM CALL DISTRIBUTION (UCD)
PROGRAMMING
DESCRIPTION DATA
For each UCD group, assign station numbers,
one by one, in the order of hunting.
NOTE: Up to 60 stations can be assigned
into a single UCD group.
Example: For setting station numbers 200,
201, 202 into one UCD group.
1st Operation (1) 200
(2) 201
2nd Operation (1) 201
(2) 202
3rd Operation (1) 202
(2) 200
(1)
(2)
Y=0
X-XXXXXXXX: Station No.
X-XXXXXXXX: Another station No. to
be linked
Assign the Pilot station and Member station.
(1)
(2)
Y=1
X-XXXXXXXX: UCD Station No.
0 : Member station
1 : Pilot station
Assign the UCD group number.
(1)
(2)
Y=2
X-XXXXXXXX: UCD Station No.
00-15: UCD Group 00-15
Specify the UCD service for each type of call.
(1)
(2)
Y=4 Internal Call
X-XXXXXXXX: Pilot Station No. of
UCD group
0: Not provided
1: To provide
(1)
(2)
Y=5 C.O. (DDD/FX/WATS) Incoming
Call
X-XXXXXXXX: Pilot Station No. of
UCD group
0: Not provided
1: To provide
START
CM17
3rd1st
2nd
200
202
201