– 721 – NWA-008845-001 Rev.5.0
32ch1011.fm
DESCRIPTION DATA
(1)
(2)
Y=6 Tie Line incoming call
X-XXXXXXXX: Pilot Station No. of
UCD group
0: Not provided
1: To provide
(1)
(2)
Y=7 DID/Automated Attendant Call
X-XXXXXXXX: Pilot Station No. of
UCD group
0: Not provided
1: To provide
(1)
(2)
Y=B Designation of number of queuing in
each UCD group
X-XXXXXXXX: Pilot Station No. of
UCD group
0 : To provide (See CM42>16)
1 : Not provided (No limit)
Specify the maximum number of queuing in
each UCD group.
(1)
(2)
16
01-99 : 1 call-99 calls
NONE : No limit
Specify the call waiting time before answer or
abandonment for PEG Count analysis.
(1)
(2)
Y=0
16
01-30: 4-120 seconds
(4 second increments)
If no data is set, the default setting is 32-36 sec-
onds.
Assign the access code for UCD station Busy
Out Set and Reset.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A044: Busy Out Set
A045: Busy Out Reset
Assign the UCD Busy Out key on the D
term
, if
required.
(1)
(2)
Y=00
My Line No. + + Key No.
F0044: UCD Busy Out
Assign the Release key on the D
term
, if re-
quired.
(1)
(2)
Y=00
My Line No. + + Key No.
F1020: Release