– 763 – NWA-008845-001 Rev.5.0
32ch2001.fm
• PMS/SMDR Interface via LAN
NOTE: The MP card in Main site communicates with the SMDR/PMS terminal. Therefore, in the com-
munication settings in SMDR/PMS terminal side, set the IP address to be connected to the ad-
dress specified by office data (CM0B Y=00>00 or CM0B Y=02>03), and application port
number shown in the above table.
ITEM SPECIFICATIONS
Physical layer Ethernet
Connection layer The Ethernet packet format complies with the DIX standard.
TCP/IP protocol ARP, IP, ICMP, UDP, TCP
Socket interface Complies with 4.3 BSD socket interface
Transport protocol TCP stream type protocol
Application port number SMDR: 60010 (fixed)
PMS : 60050 (fixed)
Number of connection 1
Client/Server Client : SMDR/PMS terminal
Server: PBX
Transmission code 7-bit ASCII code
Quasi-normal restriction condition 1. When connection is closed
2. Status monitoring text
HOTEL SYSTEM SPECIFICATIONS