– 700 – NWA-008845-001 Rev.5.0
32ch1011.fm
TIMED QUEUE
PROGRAMMING
HARDWARE REQUIRED
D
term
and DLC card
DESCRIPTION DATA
Specify the timer data for this feature.
If no data is set, the following data is applied:
Number of Call Attempts: 3 times
Interval Time of Call Attempt: 120-124 sec-
onds
Duration of Calling: 28-32 seconds
(1)
(2)
Y=0
35: Number of Times of Call Attempt
01-07: Once-7 times
If no data is set, the default setting is 3 times.
(1)
(2)
36: Interval time of Call Attempt
11-31: 48-124 seconds
(4 second increments)
If no data is set, the default setting is 120-124
seconds.
(1)
(2)
37: Duration of Calling
05-31: 20-124 seconds
(4 second increments)
If no data is set, the default setting is 28-32 sec-
onds.
Assign the Call Back feature to the required
key on the D
term
s, as required.
(1)
(2)
Y=00
My Line No. + + Key No.
F0004
START
CM41
CM90
,
END
TIMED QUEUE