– 321 – NWA-008845-001 Rev.5.0
32ch1006.fm
DIRECT INWARD TERMINATION (DIT)
PROGRAMMING
DESCRIPTION DATA
Assign the data for terminating system in Day
Mode/Night Mode/Mode A/Mode B, to each
Loop/Ground Start trunk, respectively.
•
(1)
(2)
Y=02 Day Mode/03 Night Mode/
40 Mode A/41 Mode B
000-255: Trunk No.
04: Direct-In Termination
Assign the station number to be terminated by
DIT in Day Mode/Night Mode/Mode A/Mode
B respectively.
•
(1)
(2)
Y=04 Day Mode/05 Night Mode/
42 Mode A/43 Mode B
000-255: Trunk No.
X-XXXXXXXX: Station No.
Assign the destination to be rerouted when the
DIT station is busy/not available in Day Mode
and Night Mode respectively.
•
(1)
(2)
Y=13 Day Mode/14 Night Mode
000-255: Trunk No.
01 : TAS BUZZER
04 : Attendant Console
06 : Automatic Camp-On
15 : Waiting until the DIT station be-
comes idle
Assign the transfer destination for an unan-
swered DIT call in Day Mode and Night Mode,
respectively.
•
(1)
(2)
Y=15 Day Mode/16 Night Mode
000-255: Trunk No.
01 : Attendant Console
03 : TAS
15 : To be continued DIT
Specify the timing for an unanswered call to a
DIT destination.
•
(1)
(2)
Y=0
01
01-30: 4-120 seconds
(4 second increments)
If no data is set, the default setting is 32-36
seconds.
Assign the ring cadence on a DIT call. (1)
(2)
179
0 : As per CM35 Y=33
1 : 0.4 seconds ON-0.2 seconds OFF-0.4
seconds ON-2 seconds OFF
[For North America]
Special Ringing
(See Interval of Ringing Tones by
CM08>392/CM08>396/
CM08>397. Page 337)
[For EU]
START
CM30
CM41
CM08
END
NOVEMBER/15/2006
DIRECT INWARD TERMINATION (DIT)