– 772 – NWA-008845-001 Rev.5.0
32ch2001.fm
AUTOMATIC WAKE UP
PROGRAMMING
To provide Automatic Wake Up from a guest station or administrative station, or Front Desk Terminal, or
PMS:
NOTE: PMS with AP00 on RS-232C is not available when using PN-AP00-B/PN-AP00-D with MRCA
program.
DESCRIPTION DATA
Assign Service Restriction Class A to required
guest or administrative station.
(1)
(2)
Y=02
X-XXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow Automatic Wake Up in Service Restric-
tion Class A assigned by CM12 Y=02.
(1)
(2)
Y=13 Guest station
Y=20 Administrative station allowing
single Wake Up Time operation
Y=21 Administrative station allowing
multiple Wake Up Time operation
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Allow Digital Announcement Trunk access
(Record/Replay/Delete) in the Service Restric-
tion Class A assigned by CM12 Y=02, if re-
quired.
(1)
(2)
Y=33
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
START
CM12
CM15
A
JUNE/01/2007