– 612 – NWA-008845-001 Rev.5.0
32ch1010.fm
STATION HUNTING
STATION HUNTING-CIRCULAR
PROGRAMMING
DESCRIPTION DATA
To set up each Station Hunting group, assign
station numbers, one by one, in order of the
Hunting as shown below.
Example: For setting station number 200,
201, 202 into one Hunting group.
1st Operation (1) 200
(2) 201
2nd Operation (1) 201
(2) 202
3rd Operation (1) 202
(2) 200
(1)
(2)
Y=0
X-XXXXXXXX: Station No. to be includ-
ed in Station Hunting
Group
X-XXXXXXXX: Another Station No. to
be linked
Specify the Hunting capability of each station.
To continue the hunt in the original direction,
if the station is busy, set to “1”; to reverse the
direction (last station only), set to “5”.
NOTE 1: The maximum number of stations
per hunt group is 60. And there is no
limit to the number of Circular Hunt
groups within the system.
NOTE 2: Each station can belong to only one
hunt group.
NOTE 3: The Attendant Console cannot be
member of a hunt group.
(1)
(2)
Y=1
X-XXXXXXXX: Station No.
1: If busy, hunt in original direction
5: If busy, hunt in reverse direction
Allow or restrict the ability to set Station Hunt-
ing-Circular for a station with Do Not Disturb
set.
(1)
(2)
240
0 : Allow
1 : Restricted
START
CM18
3rd1st
2nd
200
202
201
CM08
END