EasyManua.ls Logo

Philips Sopho 2000 IPS - Internal Tone;Voice Signaling

Philips Sopho 2000 IPS
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 420 – NWA-008845-001 Rev.5.0
32ch1007.fm
INTERNAL TONE/VOICE SIGNALING
PROGRAMMING
DESCRIPTION DATA
To activate the Single-Digit Feature Access
Code feature, set the data for 050, 051, 069,
148 and 543 to “1”.
(1)
(2)
050: * Button as Switch Hook Flash.
1 : Ineffective
(1)
(2)
051: # Button as Switch Hook Flash.
1 : Ineffective
(1)
(2)
069: Single Digit Dialing on BT Connec-
tion
1: Step Call
(1)
(2)
148: Same Last Digit Redialing on BT
Connection
1 : Ineffective
(1)
(2)
543: Step Call
1 : Allow
Provide the system with the Single-Digit Fea-
ture Access Code on RBT or Voice Call con-
nection.
(1)
(2)
156
0: Available
Specify if Voice Call is provided when calling
a D
term
is set to Voice First from a Single-Line
Telephone or a D
term
without an LCD.
(1)
(2)
270
0 : Not provided (Busy Tone)
1: To provide
Provide the system with the Single-Digit Fea-
ture Access Code on BT connection.
(1)
(2)
208
0: Available
Specify whether the access codes of Single-
Digit Feature Access Code feature are fixed or
not.
[Series 3600 software required]
(1)
(2)
570
0 : Programmable Access Code
1 : Fixed Access Code
When using programmable access code
(CM08>570 is set to 0), assign the Single-
Digit Feature Access Code for the RBT con-
nection.
[Series 3600 software required]
(1)
(2)
Y=5
X: Access code (0-9, A (*), B (#))
1 : Internal Tone/Voice Signaling
NONE : Single-Digit Feature Access
Code is not available
START
CM08
CM20
A
JULY/01/2006
INTERNAL TONE/VOICE SIGNALING

Table of Contents