– 553 – NWA-008845-001 Rev.5.0
32ch1009.fm
OFF-HOOK ALARM
PROGRAMMING
DESCRIPTION DATA
Provide Off-Hook Alarm for the required sta-
tions.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
0: To provide
Assign the destination for Off-Hook Alarm to
a station or Attendant Console.
(1)
(2)
Y=12
00-63: Tenant No.
X-XXXXXXXX: Station No.
E000 : Attendant Console
If the Attendant Console is designated as the
destination of Off-Hook Alarm by CM51
Y=12, assign Off-Hook Alarm to the ICI key.
(1)
(2)
Y=00
ATTCON No. (E000-E007) + + Key
No.
F6066: Off-Hook Alarm
Specify the timing for Off-Hook Alarm.
(1)
(2)
Y=0
22
01-08: 4-32 seconds
(4 second increments)
If no data is set, default setting is 28-32 seconds.
Specify Service Restriction Class C for Off-
Hook Alarm to busy destination.
(1)
(2)
Y=07
X-XXXXXXXX: Station No. of destina-
tion
00-15 : Service Restriction Class C
Allow the Off-Hook Alarm call in Service Re-
striction Class C assigned by CM12 Y=07.
(1)
(2)
Y=97, 98
00-15: Service Restriction Class C as-
signed by CM12 Y=07
See left column.
START
CM13
CM51
CM90
,
CM41
CM12
CM15
Y
MEANING OF DATA
97 98
00
UCD Call Waiting
(CM08>212: 0)
Call Waiting is automatically
selected, if UCD is not pro-
vided in the system.
0 1 UCD (CM08>212: 1)
1 0 Call Waiting
1 1 Hunting
END
OFF-HOOK ALARM

Table of Contents