– 86 – NWA-008845-001 Rev.5.0
32ch1002.fm
AUTHORIZATION CODE
PROGRAMMING
DESCRIPTION DATA
Specify the processor for this feature. (1)
(2)
216: Processor for Authorization Code
0: MP card
1 : OAI (ACF)
Specify whether Service Set Tone should be
provided after dialing the access code for
Authorization Code.
(1)
(2)
362: Service Set Tone after dialing the ac-
cess code
0: No tone
1 : Service Set Tone
Assign Service Restriction Class A for Autho-
rization Code to the required stations.
(1)
(2)
Y=02
X-XXXXXXXX: My Line No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow Authorization Code in Service Restric-
tion Class A assigned by CM12 Y=02.
(1)
(2)
Y=31 Authorization Code
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Specify the entry of Authorization Code after
dialing an LCR access code and desired
number.
[Series 3900 software required]
NOTE: To provide this operation, the
following data assignments are
required.
- Toll restriction
(CM12 Y=01,
CM8A Y=5XXX: 000, CM81)
- LCR origination
(CM20: A126/A127/A128/A129,
CM8A Y=5XXX: 180, CM85)
(1)
(2)
Y=401
00-15: Service Restriction Class A as-
signed by CM12 Y=02
0 : Allow
7 : Restricted
Assign the access code for Authorization
Code.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A086: Authorization Code
START
CM08
CM12
CM15
CM20
A
JUNE/01/2007
AUTHORIZATION CODE

Table of Contents