EasyManua.ls Logo

Philips Sopho 2000 IPS - Overflow for Tas Queue

Philips Sopho 2000 IPS
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 539 – NWA-008845-001 Rev.5.0
32ch1009.fm
OVERFLOW FOR TAS QUEUE
PROGRAMMING
In addition to the TAS programming ( Page 543), do the following programming.
HARDWARE REQUIRED
When a DAT is used as the destination of Call Forwarding:
DAT card or MP card (built-in DAT)
DESCRIPTION DATA
Assign the destination of Call Forwarding by
Overflow for TAS Queue.
(1)
(2)
Y=26 Day Mode
Y=27 Night Mode
Y=28 Mode A
Y=29 Mode B
00-63: Tenant No.
X-XXXXXXXX: Station No.
E000 : Attendant Console
EB000-EB127 : Digital Announcement
Trunk No. assigned by
CM10/CM14
Specify the timing of Call Forwarding by
Overflow for TAS Queue.
(1)
(2)
Y=0
42
01-99: 4-396 seconds
(4 second increments)
If no data is set, the default setting is 28-32 sec-
onds.
When a call is forwarded to the VMS/station/
Attendant Console by Overflow for TAS
Queue, assign the Call Forwarding setting sta-
tion number, which is sent to the destination.
(1)
(2)
Y=30
00-63: Tenant No.
X-XXXXXXXX: Station No.
When a Digital Announcement Trunk is set as
the destination of Call Forwarding, set the
function of the Digital Announcement Trunk
as announcement service for Overflow for
TAS Queue.
(1)
(2)
Y=00
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
Card No. (EB002-EB127) as-
signed by CM10/CM14
1800: Announcement Service for Overflow
for TAS Queue
START
CM51
CM41
CM51
CM49
END
NIGHT SERVICE
OVERFLOW FOR TAS QUEUE

Table of Contents