– 548 – NWA-008845-001 Rev.5.0
32ch1009.fm
NO CID CALL ROUTING
[Series 3600 software required]
For Direct Inward Dialing calls
DESCRIPTION DATA
Assign the indication of reason why the calling
number is not informed from network to trunk
route.
(1)
(2)
Y=133
00-63: Trunk Route No.
0: To indicate
Assign whether the call terminating method is
specified for DID incoming call with no CLI.
NOTE: Assign the call terminating method
by CM76 Y=34/36 when this com-
mand is set to 0/1.
(1)
(2)
Y=33 (For Day Mode)
Y=35 (For Night Mode/Mode A/Mode B)
000-999: Block No.
0 : Specified when reason of the incom-
ing call with no CLI is “privacy”
1 : Specified for all incoming calls with
no CLI
3 : Not specified
Assign the specification of the call terminating
method for DID incoming call with no CLI.
(1)
(2)
Y=34 (For Day Mode)
Y=36 (For Night Mode/Mode A/Mode B)
000-999: Block No.
0 : To transfer to the DAT/another station/
Attendant console (assigned by CM51
Y=33)
1 : To reject the call termination
2 : To terminate the D
term
with unusual
LED indication/unusual ringer tone/
unusual ringer pattern (assigned by
CM76 Y=37, 38, 39)
3 : To terminate as usual
START
CM35
CM76
A
JULY/01/2006
NO CID CALL ROUTING

Table of Contents