– 81 – NWA-008845-001 Rev.5.0
32ch1002.fm
ATTENDANT OVERFLOW
PROGRAMMING
DESCRIPTION DATA
Provide the system with Attendant Overflow. (1)
(2)
067
0: Available
Assign the data for terminating system in Day/
Night Mode for each trunk.
(1)
(2)
Y=02 Day Mode
000-255: Trunk No.
14: Termination to Attendant Console
(1)
(2)
Y=03 Night Mode
000-255: Trunk No.
04: Direct-in Termination
(1)
(2)
Y=05 Night Station Assignment
000-255: Trunk No.
X-XXXXXXXX: Station No.
Specify the timing interval for Attendant Over-
flow.
(1)
(2)
Y=0
01
01-30: 4-120 seconds
(4 second increments)
If no data is set, the default setting is 32-36 sec-
onds.