– 445 – NWA-008845-001 Rev.5.0
32ch1008.fm
PEG COUNT
PROGRAMMING
Refer to “Command Manual”. (CMB0, CMB3)
DESCRIPTION DATA
Assign the setting/changing of the password to
be allowed.
(1)
(2)
8
0 : Allowed
1 : Restricted
Assign a password to each Password Level. (1)
(2)
0-7: Password Level 0-7
X-X...X: Maximum 8 digits Password
CCC : Password clear
A password for Password Level 7 should be as-
signed in advance because of providing the
password service by Function No. 9 of CME9.
The following passwords are not available.
“CCCCCCCC”
“FFFFFFFF”
The setting/changing of the password is avail-
able only when the second data of CME9>8 is
set to “0 (Allowed)”.
If CME9>8 is set to “1 (Restricted)”, “DATA
ERROR” is displayed when you set/change the
password.
Provide the system with Password feature. Af-
ter setting this data, access to system program-
ming will be available with password entry.
(1)
(2)
9
0: Provided
A
CME9
END
DECEMBER/02/2005
MAINTENANCE ADMINISTRATION TERMINAL (MAT)
PASSWORDS/PEG COUNT