– 538 – NWA-008845-001 Rev.5.0
32ch1009.fm
NIGHT CONNECTION-FIXED
NIGHT CONNECTION-FLEXIBLE
PROGRAMMING
To Provide Night Connection Stations:
DESCRIPTION DATA
Assign a Night Connection Station to each in-
coming trunk.
(1)
(2)
Y=03
000-255: Trunk No.
04: Direct-In Termination
(1)
(2)
Y=05
000-255: Trunk No.
X-XXXXXXXX: Night Connection Sta-
tion No.
Assign the destination to which a call is for-
warded when the Night Connection Station is
busy/no answer.
(1)
(2)
Y=14 When Night Connection Station is
busy
000-255: Trunk No.
01 : To TAS
04 : To Attendant Console
06 : Automatic Camp-On
15 : Keep the call ringing until the station
becomes idle
(1)
(2)
Y=16 When Night Connection Station is no
answer
000-255: Trunk No.
01 : To Attendant Console
03 : To TAS
15 : Keep the call ringing until the station
answers
Specify the timing for a call forwarding when
the Connection Station is no answer.
NOTE: This timing is also applied to Call
Forwarding-No Answer, Attendant
Overflow, and Group Diversion.
(1)
(2)
Y=0
01
01-30: 4-120 seconds
(4 second increments)
If no data is set, the default setting is 32-36 sec-
onds.
START
CM30
CM41
END