– 116 – NWA-008845-001 Rev.5.0
32ch1002.fm
DESCRIPTION DATA
Assign the automatic clock change pattern to
each location number.
(1)
(2)
Y=31
00-63: Location No.
0 : Change Pattern 0 (assigned by
CM43 Y=8>00/01)
1 : Change Pattern 1 (assigned by
CM43 Y=8>04/05)
NONE : Automatic clock change is not
provided
Set the daylight-saving time to each location.
NOTE:
Usually do not set this command by
MAT/CAT. This command is set auto-
matically when automatic system clock
change has been executed by CM43
Y=8/CM67 Y=31
.
If the system power is off at the time
for clock change, set this data.
(1)
(2)
Y=30
00-63: Location No.
0 : To operate with Daylight-Saving
Time
NONE : To operate with Standard Time
Specify the system clock used for the SMDR
output of outgoing/incoming call.
(1)
(2)
836
0 : System clock of the site that the seized
trunk is accommodated (for outgoing
call)/System clock of site that the ter-
minated trunk is accommodated (for
outgoing call)
1 : System clock of Main Site
Specify the system clock used for the SMDR
output of station to station call.
(1)
(2)
837
0 : System clock of the site that the seized
trunk/calling station is accommodated
1 : System clock of Main Site
Specify the system clock used for the date pat-
tern/time pattern in LCR service.
(1)
(2)
904
0 : System clock of the site that the seized
trunk/calling station is accommodated
1 : System clock of Main Site
B
CM67
CM08
END