– 141 – NWA-008845-001 Rev.5.0
32ch1003.fm
HARDWARE REQUIRED
D
term
and DLC card if required
DESCRIPTION DATA
Specify the setting method for Call Forward-
ing-Busy Line-Outside.
(1)
(2)
222
0 : Setting when the station goes on hook/
when receiving Service Set Tone
(ORT time out)
1 : Setting when receiving Service Set
Tone (ORT time out)
Allow or restrict the ability to set Call For-
warding-Busy Line for a station with Do Not
Disturb set.
(1)
(2)
240
0 : Allowed
1 : Restricted
Assign whether an extension can set a destina-
tion of Call Forwarding-Busy Line-Outside by
entering only a trunk access code.
(1)
(2)
386
0 : Restricted
1 : Allowed
Select the trunk route seized for Call Forward-
ing-Busy Line-Outside.
(1)
(2)
600
0 : By calling party’s tenant/terminating
trunk’s tenant
1 : By Call Forwarding setting station’s
tenant
Assign Call Forwarding-Busy Line keys to the
D
term
, as required.
•
(1)
(2)
Y=00
My Line No. + + Key No.
F0014: Call Forwarding-Busy Line Set/
Cancel
(1)
(2)
For setting the same key as Call Forward-
ing-No Answer
My Line No. + + Key No.
F0012: Call Forwarding-No Answer/Busy
Line Set/Cancel
Provide Call Forwarding feature with each
tenant as per incoming call type.
•
•
•
(1)
(2)
Y=23 Internal Call or ATT assisted Call
Y=24 C.O. Incoming Call
Y=25 Tie Line Incoming Call
00-63: Tenant No.
1 : Call Forwarding
A
CM08
CM90
,
,
CM65
END
CALL FORWARDING
CALL FORWARDING-BUSY LINE