– 284 – NWA-008845-001 Rev.5.0
32ch1005.fm
DESCRIPTION DATA
(1)
(2)
Y=01 Dialing signal type
00-63: Trunk Route No.
7 : DP/DTMF (Incoming)
DTMF (Outgoing)
(1)
(2)
Y=04 Answer signal from distant office
00-63: Trunk Route No.
2: Answer signal arrives
(1)
(2)
Y=05 Release signal from distant office
00-63: Trunk Route No.
1 : Release signal arrives
(1)
(2)
Y=09 Incoming connection signaling
00-63: Trunk Route No.
03: Wink Start
04: Delay Dial
05: Immediate Start
06: 2nd DT/Timing Start-Tie line
CM35 Y=19 DTI PAD
(1)
(2)
Y=19 DTI PAD
00-63: Trunk Route No.
0-3 : Programmable PAD (See CM42)
4-7 : Fixed PAD (See left table)
(1)
(2)
Y=20 Sender start condition
00-63: Trunk Route No.
00 : Wink Start
01 : Delay Dial
02 : Ground Start
15 : Timing Start
B
CM35
T/R: Transmitter PAD/Receiver PAD
+: Gain
–: Loss
CONNECTION
PATTERNS
PAD DATA OF DTI [dB]
DAT
A=4
(T/R)
DAT
A=5
(T/R)
DAT
A=6
(T/R)
DAT
A=7
(T/R)
Station-DTI –3/–8 –3/–3 –3/–3 –3/–8
Tone-DTI 0/0 0/0 0/0 0/0
COT/DID/ODT
(2W E&M)/IPT-
DTI
0/0 0/0 0/0 0/0
ODT (4W E&M)-
DTI
+3/–3 0/0 0/0 +3/–3
DTI/BRT/PRT/
CCT/Virtual IPT-
DTI
0/–6 0/0 0/–6 0/0
C
JULY/01/2006
DIRECT DIGITAL INTERFACE
PROGRAMMING

Table of Contents