– 296 – NWA-008845-001 Rev.5.0
32ch1005.fm
DESCRIPTION DATA
Specify the various timing parameters, if
required.
(1)
(2)
Y=3
00: Release Signal Detect Timing
01-15: 64-960 ms. (64 ms. increments)
If no data is set, the default setting is 128 ms.
(1)
(2)
Y=3
01: Answer Signal Detect Timing
01-15: 32-480 ms. (32 ms. increments)
If no data is set, the default setting is 128 ms.
(1)
(2)
Y=3
02: Wink Signal width
01-15: 64-512 ms. (32 ms. increments)
If no data is set, the default setting is 32 ms.
(1)
(2)
Y=3
03: Wink/Delay Detection Timeout
01-15: 1-15 seconds (1 second increments)
If no data is set, the default setting is 7 seconds.
Assign an access code for the DTI trunk route.
NOTE: The Least Cost Routing or Route
Advance feature is also available
for call origination via the DTI.
Refer to the following feature
programming.
LEAST COST ROUTING-3/6
DIGIT Page 425
ROUTE ADVANCE
Page 599
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
100-163: Trunk Route 00-63
C
CM41
CM20
END