– 328 – NWA-008845-001 Rev.5.0
32ch1006.fm
(4) For Direct Inward Dialing calls
To distinguish by the trunk route
To distinguish by the terminating DID number
DESCRIPTION DATA
Specify the interval of ringing tones for Direct
Inward Dialing calls.
(1)
(2)
180
0 : 0.4 seconds ON-0.2 seconds OFF-0.4
seconds ON-2 seconds OFF
1 : As per CM35 Y=33
DESCRIPTION DATA
Assign the interval of ringing tones as “As per
CM76 Y=22”.
(1)
(2)
180
1 : As per CM76 Y=22
Specify the interval of ringing tones on DID
calls.
For this assignment, do not set CM76 Y=22 to
3 (As per CM35 Y=33 (D
term
or SLT)).
(1)
(2)
Y=22
000-999: Number Conversion Block No.
assigned by CM76 Y=00/90
0: 0.5 seconds ON-0.5 seconds OFF
(D
term
)
1.0 second ON-2.0 seconds OFF (SLT)
1: 0.5 seconds ON-0.5 seconds OFF-
0.5 seconds ON-1.5 seconds OFF
(D
term
)
0.4 seconds ON-0.2 seconds OFF-
0.4 seconds ON-2.0 seconds OFF (SLT)
2: 1.0 second ON-2.0 seconds OFF (D
term
or SLT)
START
CM08
END
START
CM08
CM76
END
DISTINCTIVE RINGING