– 330 – NWA-008845-001 Rev.5.0
32ch1006.fm
(7) For ISDN Indial calls
To distinguish by the trunk route
To distinguish by the terminating ISDN Indial number
DESCRIPTION DATA
Specify the interval of ringing tones for station
on incoming calls.
NOTE: For incoming calls to a Trunk-Di-
rect Appearances key on D
term
s, the
special ringing; 0.2 seconds ON-0.2
seconds OFF will be applied.
(1)
(2)
Y=33
00-63: Trunk Route No.
0 : 0.4 seconds ON-0.2 seconds OFF-0.4
seconds ON-2 seconds OFF
1 : 0.4 seconds ON-0.2 seconds OFF-0.4
seconds ON-2 seconds OFF
2 : 1 second ON-2 seconds OFF
3 : 2 seconds ON-4 seconds OFF
DESCRIPTION DATA
Assign the interval of ringing tones as “As per
CM76 Y=22”.
(1)
(2)
180
1 : As per CM76 Y=22
Specify the interval of ringing tones on ISDN
Indial calls.
For this assignment, do not set CM76 Y=22 to
3 (As per CM35 Y=33 (D
term
or SLT)).
(1)
(2)
Y=22
000-999: Number Conversion Block No.
assigned by CM76 Y=00/90
0: 0.5 seconds ON-0.5 seconds OFF
(D
term
)
1.0 second ON-2.0 seconds OFF (SLT)
1: 0.5 seconds ON-0.5 seconds OFF-
0.5 seconds ON-1.5 seconds OFF
(D
term
)
0.4 seconds ON-0.2 seconds OFF-
0.4 seconds ON-2.0 seconds OFF (SLT)
2: 1.0 second ON-2.0 seconds OFF (D
term
or SLT)
START
CM35
END
START
CM08
CM76
END
DISTINCTIVE RINGING

Table of Contents