– 344 – NWA-008845-001 Rev.5.0
32ch1006.fm
DESCRIPTION DATA
Provide the distinctive ringing patterns to a
D
term
in behind PBX.
•
(1)
(2)
Y=87
00-63: Trunk Route No.
0: To provide
1: Not provided
Specify the terminating system for incoming
C.O. calls.
•
•
•
•
(1)
(2)
Y=02 in Day Mode
Y=03 in Night Mode
Y=40 in Mode A
Y=41 in Mode B
000-255: Trunk No.
02: Trunk-Direct Appearances
03: Trunk-Direct Appearances + TAS
Provide the Trunk-Direct Appearances on
D
term
.
•
(1)
(2)
Y=18
000-255: Trunk No.
0: To provide
1: Not provided
Assign the ringing detect timer for incoming
trunk calls.
•
(1)
(2)
Y=2
00
06-10: 192-320 ms.
(32 ms. increments)
If no data is set, the default setting is 256-288
ms.
Assign the main PBX (Centrex) ringing
distinction timer. NOTE 1 on next page
•
(1)
(2)
Y=2
40
01-15: 128-1920 ms.
(128 ms. increments)
If no data is set, the default setting is 1280-1408
ms.
Assign the immediate ringing guard timer
from the main PBX (Centrex).
NOTE 1, NOTE 2 on next page
•
(1)
(2)
Y=2
41
00-90: 0-12672 ms.
(128 ms. increments)
If no data is set, the default setting is 384-512
ms.
C
CM35
CM30
CM41
D
DISTINCTIVE RINGING