– 500 – NWA-008845-001 Rev.5.0
32ch1008.fm
To specify a D
term
ringer tone pattern of Mobility Access call, do the following programming.
DESCRIPTION DATA
Specify the Ringer Tone Pattern of the D
term
on DID calls.
(1)
(2)
Y=23
000-999: Number Conversion Block No.
0 : Ringer Tone Pattern 0
1 : Ringer Tone Pattern 1
2 : Ringer Tone Pattern 2
3 : Ringer Tone Pattern 3
4 : Ringer Tone Pattern 4
5 : Ringer Tone Pattern 5
6 : Ringer Tone Pattern 6
7 : As per CM35 Y=34/164
Specify the Ringer Tone Pattern of the D
term
to
each trunk route.
(1)
(2)
Y=34, 164
00-63: Trunk Route No.
See the table below.
START
CM76
CM35
Y=34 Y=164: 0 Y=164: 1
0 Ringer Tone Pattern 3 Ringer Tone Pattern 0
1 Ringer Tone Pattern 6 Ringer Tone Pattern 1
2 Ringer Tone Pattern 5 Ringer Tone Pattern 2
3 Ringer Tone Pattern 4 Ringer Tone Pattern 7