– 573 – NWA-008845-001 Rev.5.0
32ch1009.fm
DESCRIPTION DATA
When connecting D16 (LD)-R ADM to D
term
Series i 16LD and using it as One Touch keys/
Directories, allocate the memory area for D
term
One Touch keys to each station.
(1)
(2)
X-XXXXXXXX: My Line No.
W XX 0 ZZ
W : 0-9: 1000-Slot Memory Block No.
XX: 00-99: 10-Slot Memory Start Block
No.
ZZ : 01/02: Number of 10-Slot Memory
Blocks (10 memories/20 memories)
NONE : No data
NOTE 1: To provide the D16 (LD)-R ADM with D
term
Series i 16LD, Series 3500 software is re-
quired.
NOTE 2: Station Speed Dialing and D
term
One Touch keys uses the common memory area. Be sure
to allocate the different memory area by CM94 from the memory area set by CM73.
NOTE 3: If the station number is assigned to One Touch keys using 1000-Slot Memory Block number
4-9, the lamp does not show the busy state.
Provide to send the indication data to Line Key
LCD of D
term
Series i 16LD.
(1)
(2)
Y=29
X-XXXXXXXX: My Line No.
0: To send indication data
C
CM94
0
9
1
Memory Parcel
00
99
01
10-Slot
Memory Block
0
~~
3
4
1000-Slot
Memory Block
4000 Memory
9
Parcels
6000 Memory
Parcels
CM12
END