– 597 – NWA-008845-001 Rev.5.0
32ch1009.fm
Remote Hold from a DESKCON:
DESCRIPTION DATA
Provide Remote Hold from DESKCON ser-
vice.
(1)
(2)
705
0: Available
Specify the recall timing for Remote Hold
from DESKCON.
(1)
(2)
Y=0
00
00-14: 2.4-33.6 seconds
(2.4 second increments)
15-24: 38.4-124.8 seconds
(9.6 second increments)
If no data is set, default setting is 31.2-33.6 sec-
onds.
START
CM08
CM41
END
REMOTE HOLD