To provide an External Announcement Machine via COT card:
DESCRIPTION DATA
Assign Service Restriction Class A for Timed
Reminder to the required stations.
•
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow Timed Reminder in Service Restriction
Class A assigned by CM12 Y=02.
•
(1)
(2)
Y=13
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Assign the access code for Timed Reminder
set and cancel.
•
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code (5*, 5#)
A024: Timed Reminder Set
A025: Timed Reminder Cancel
Assign the COT card and DK card to the re-
quired LEN.
NOTE 1: The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
(1)
(2)
000-763: LEN
DB00-DB09: Interface Card No. for Exter-
nal Announcement Machine
E800-E831 : DK Card No.
For PIM0/1 : E800-E807
For PIM2/3 : E808-E815
For PIM4/5 : E816-E823
For PIM6/7 : E824-E831
NOTE 2: Circuit No. 3 of E831 is used for
built-in External Equipment In-
terface on MP card by setting
CM44.
Assign the COT card and DK card to the re-
quired LEN.
[Series 3200 R6.2 software required]
NOTE 1: The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
(1)
(2)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
DB00-DB09: Interface Card No. for Exter-
nal Announcement Machine
E800-E831 : DK Card No.
For FP No. 00: E800-E807
For FP No. 01: E808-E815
For FP No. 02: E816-E823
For FP No. 03: E824-E831
NOTE 2: Circuit No. 3 of E831 is used for
built-in External Equipment In-
terface on MP card by setting
CM44.
START
CM12
CM15
CM20
CM10
CM14
A
TIMED REMINDER