– 725 – NWA-008845-001 Rev.5.0
32ch1011.fm
To provide an external indicator for UCD Call Waiting:
DESCRIPTION DATA
Assign the incoming call to queuing mode
when all UCD stations are busy.
(1)
(2)
212
1: Queuing
Specify the maximum number of queuing in
each UCD group for controlling external indi-
cator.
(1)
(2)
15
01-99 : 1 call-99 calls
NONE : 1 call
NOTE: Depending on the number of queuing station/trunk, lamp indication pattern on the external
indicator is different as shown below:
N=Number of queuing station/trunk
Assign the DK card to the required LEN.
NOTE 1: The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
(1)
(2)
000-763: LEN
E800-E831: DK Card No.
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
NOTE 2: Circuit No. 3 of E831 is used for
built-in External Equipment Interface
on MP card by setting CM44.
Assign the DK card to the required LEN.
[Series 3200 R6.2 software required]
NOTE 1: The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
(1)
(2)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
E800-E831: DK Card No.
For FP No. 00: E800-E807
For FP No. 01: E808-E815
For FP No. 02: E816-E823
For FP No. 03: E824-E831
NOTE 2: Circuit No. 3 of E831 is used for
built-in External Equipment Interface
on MP card by setting CM44.
START
CM08
CM42
CONDITIONS LAMP INDICATION
2nd Data=01 Lamp on irrespective of number of queuing station/trunk (For the indi-
cation pattern, see CM59 in next page.)
N
<2nd Data (2nd Data≠01) Lamp off
2nd Data
≤N (2nd Data≠01) Lamp on (For the indication pattern, see CM59 in next page.)
CM10
CM14
A
UNIFORM CALL DISTRIBUTION (UCD)
CALL WAITING INDICATION-UCD