– 728 – NWA-008845-001 Rev.5.0
32ch1011.fm
DESCRIPTION DATA
If the data for CM17 Y=A is “0”, set the inter-
val time for UCD Delay Announcement.
(1)
(2)
Y=0
47
01-30: 4-120 seconds
(4 second increments)
If no data is set, the default setting is 32-36 sec-
onds.
Specify the UCD Delay Announcement con-
nection timer.
(1)
(2)
Y=0
67
01-32: 4-128 seconds
(4 second increments)
If no data is set, the default setting is 8-12 sec-
onds.
Specify the maximum UCD call waiting time
before answer or abandonment for UCD PEG
Count, and waiting time before UCD Delay
Announcement.
(1)
(2)
Y=0
16
01-30: 4-120 seconds
(4 second increments)
If no data is set, the default setting is 32-36 sec-
onds.
Assign the UCD Delay Announcement func-
tion to the required Digital Announcement
Trunk.
(1)
(2)
Y=00
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
Card No. (EB002-EB127)
assigned by CM10/CM14
0B0XX : UCD Delay Announcement
11XX : UCD Second Delay Announce-
ment
XX : 00-15: UCD group No.
To record, replay and delete a message, assign
the Digital Announcement Trunk access code,
respectively.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access code
A100: Record
A101: Replay
A102: Delete
When transferring the call to a station or Atten-
dant after the 1st interval time of UCD Delay
Announcement, assign the destination.
(1)
(2)
Y=17
00-63: Tenant No.
Destination:
X-XXXXXXXX: Station No.
E000 : Attendant Console
A
CM41
CM49
CM20
CM51
A
UNIFORM CALL DISTRIBUTION (UCD)
DELAY ANNOUNCEMENT-UCD