– 747 – NWA-008845-001 Rev.5.0
32ch1011.fm
NOTE 1: While both Message Waiting and Call Forwarding-All Calls/Do Not Disturb Service are set to
the station, the message assigned by CM49 Y=13>00 is sent.
NOTE 2: While Message Reminder (from station/attendant) Service is set to the station, the message
assigned by CM49 Y=13>00 is sent.
NOTE 3: While Split Call Forwarding-All Calls Service is set to the station, the message assigned by
CM49 Y=13>03 is sent.
To provide the Message which is sent when the service feature setting to the station is completed or can-
celed:
HARDWARE REQUIRED
DAT card or MP card (Built-in DAT)
DESCRIPTION DATA
Assign the Voice Guide function for each Dig-
ital Announcement Trunk card.
(1)
(2)
Y=00
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
Card No. assigned by CM10/
CM14 (EB002-EB127)
17XX: Voice Guide
XX : 00-63: Message No.
Assign the Message number when service set-
ting is completed or canceled to station.
(1)
(2)
Y=13
01: Message sent when service is set
02: Message sent when service is canceled
00-63: Message No.
Message Replay Timer for Announcement
Service.
(1)
(2)
Y=0
53
01-99: 4-396 seconds
(4 second increments)
If no data is set, the default setting is 60-64 sec-
onds.
START
CM49
CM41
END
VOICE GUIDE

Table of Contents