– 814 – NWA-008845-001 Rev.5.0
32ch2001.fm
HARDWARE REQUIRED
AP00-B card with AP00 program or AP00-B/AP00-D card with MRCA program
Front Desk Terminal or
PMS
RS RVS-15S CA/RS RVS-4S CA/RS NORM-4S CA (for PMS with AP00 on RS-232C)
DESCRIPTION DATA
(1)
(2)
X 04: Check In time delete
X : 1-8: Room Status Code
0 : Not deleted
1 : To delete
(1)
(2)
X 05: Maid Identification number set/
change
X : 1-8: Room Status Code
0 : Not available
1 : Available
(1)
(2)
X 06: Hotel/Motel Toll Restriction
Change-Guest Station
X : 1-8: Room Status Code
0 : Not available
1 : Unrestricted (RCA)
2 : Non-Restricted 1 (RCB)
3 : Non-Restricted 2 (RCC)
4 : Semi-Restricted 1 (RCD)
5 : Semi-Restricted 2 (RCE)
6 : Restricted 1 (RCF)
7 : Restricted 2 (RCG)
8 : Fully-Restricted (RCH)
9 : Restriction reset (As per CM12 Y=01)
(1)
(2)
X 07: Check Out lamp control on DSS
Console
X : 1-8: Room Status Code
0 : Not controlled
1: Lamp OFF
2 : Flash (slowly)
3 : Flash (120IPM)
4: Lamp ON
B
CMDD31
END