– 816 – NWA-008845-001 Rev.5.0
32ch2001.fm
DESCRIPTION DATA
Specify the type of answer signal from distant
office in outgoing connection for each trunk
route.
(1)
(2)
Y=04
00-63: Trunk Route No.
1 : Battery Reversal from C.O. line
2 : Answer signal arrives from Tie Line/
ISDN
7 : Answer signal does not arrive
Provide SMDR service for outgoing calls to re-
quired trunk routes.
(1)
(2)
Y=14
00-63: Trunk Route No.
1: To provide
Assign a trunk access code for SMDR.
(1)
(2)
Y=44
00-63: Trunk Route No.
00-99: Trunk Access Code
Specify the timing of SMDR valid call timer
(pseudo-answer timer).
(1)
(2)
Y=0
03
01-08: 4-40 seconds
(4 second increments)
If no data is set, the default setting is 20-24 sec-
onds.
Send message to PMS, if a checked out station
is originating a C.O. call.
(1)
(2)
88
0: Not sent
1: To send
Assign the charging Service Class number to
each station number, if PMS with AP00 on RS-
232C is provided.
(1)
(2)
X-XXXX: Station No.
00 -15: Service Class No.
Send detail call information on outgoing calls
to SMDR, if PMS with AP00 on RS-232C is
provided.
(1)
(2)
XX 16
XX: Service Class No. assigned by
CMD015
1: To send
Assign the Development Table number to out-
going trunk routes, if PMS with AP00 on RS-
232C is provided.
(1)
(2)
00-63: Trunk Route No.
000 -511: Development Table No.
A
CM35
CM41
CMD000
CMD015
CMD016
CMD026
B
NOVEMBER/15/2006
HOTEL SYSTEM PROGRAMMING
MESSAGE REGISTRATION

Table of Contents