– 824 – NWA-008845-001 Rev.5.0
32ch2001.fm
To provide MP built-in PMS on IP:
[Series 3400 software required]
NOTE: The MP card (or the MP card in a Main Site when Remote PIM over IP feature is provided)
communicates with the PMS terminal. For the settings in the PMS terminal side, set IP address
assigned by CM0B Y=00 (or CM0B Y=02 when VLAN is provided) as a destination of the PMS
terminal, and set “60050” as the port number.
DESCRIPTION DATA
Assign the system clock data. (1)
(2)
0: Calendar Year
2000-2099
(1)
(2)
1: Date
MM DD WW
MM : 01-12 (Month)
DD : 01-31 (Date)
WW: 00 (Sun)
01 (Mon)
02 (Tue)
03 (Wed)
04 (Thu)
05 (Fri)
06 (Sat)
(1)
(2)
2: Time
HH MM SS
HH : 00-23 (Hour)
MM: 00-59 (Minute)
SS : 00-59 (Second)
Assign the IP Address for the system. •
(1)
(2)
Y=00
00
000000000000-255255255255:
IP Address for the system
START
CM02
CM0B
INITIAL
A
HOTEL SYSTEM PROGRAMMING
PROPERTY MANAGEMENT SYSTEM INTERFACE