Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library
Scalar i500 User’s Guide 378
a From the front of the library, open the I/E station and access
doors of the expansion module. Squeeze the handle of the Y-rail
release mechanism, lift it out of its locked position, and slide it
downward as far as it will go.
b From the back of the library, find the rear Y-rail release
mechanism, which is located in the interior of the right side of the
module. Squeeze the handle of the Y-rail release mechanism, lift
it out of its locked position, and slide it downward as far as it will
go.
Doing this aligns the Y-rails with the Y-rails of the module
beneath it.
Caution: Check to make sure that there is no gap between the top
and bottom Y-rails on both the front and back of the
library. If a gap exists, the library cannot mechanically
initialize.

Table of Contents

Other manuals for Quantum Scalar i500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i500 and is the answer not in the manual?

Quantum Scalar i500 Specifications

General IconGeneral
Form FactorRack-mountable
Product TypeTape Library
WeightVaries by configuration
Power ConsumptionVaries by configuration
Drive SupportLTO-8, LTO-7, LTO-6
ManagementWeb-based remote management
Drive TypeLTO Ultrium
Supported MediaLTO-5, LTO-6, LTO-7, LTO-8
Operating Temperature10°C to 35°C
Humidity20% to 80% (non-condensing)
InterfaceSAS

Related product manuals