Receiver Mode
R&S
®
ESR
212User Manual 1175.7068.02 ─ 12
Remote command:
CALCulate<n>:LIMit<k>:COPY on page 706
Delete
Deletes the selected limit line.
Remote command:
CALCulate<n>:LIMit<k>:DELete on page 707
X Offset
Horizontally shifts a limit line that has been specified for relative frequencies or times
(x-axis). The softkey opens an edit dialog box in which the value for shifting can be
entered numerically or via the rotary knob.
Note: This softkey does not have any effect on limit lines that represent absolute val-
ues for the x-axis.
Remote command:
CALCulate<n>:LIMit<k>:CONTrol:OFFSet on page 710
Y Offset
Vertically shifts a limit line that has relative values for the y-axis (levels or linear units
such as volt). The softkey opens an edit dialog box in which the value for shifting can
be entered numerically or via the rotary knob.
Note: This softkey does not have any effect on limit lines that represent absolute val-
ues for the y-axis.
Remote command:
CALCulate<n>:LIMit<k>:LOWer:OFFSet on page 712
CALCulate<n>:LIMit<k>:UPPer:OFFSet on page 715
Display Lines
Opens a submenu to enable, disable and set display lines. Which softkeys are availa-
ble depends on the display mode (frequency or time range).
For details see also Chapter 5.4.3.2, "Display Lines", on page 213 and Chap-
ter 5.4.3.4, "Working with Lines", on page 215.
The submenu contains the following functions:
●
"Display Line 1 / Display Line 2" on page 212
●
"Display Line 1 / Display Line 2" on page 212
●
"Frequency Line 1 / Frequency Line 2 " on page 213
●
"Frequency Line 1 / Frequency Line 2 " on page 213
●
"Time Line 1 / Time Line 2" on page 213
●
"Time Line 1 / Time Line 2" on page 213
●
"Tuned Frequency (On Off)" on page 213
Display Line 1 / Display Line 2 ← Display Lines
Enables or disables the level lines 1/2 and opens an edit dialog box to enter the posi-
tion of the lines.
For details see also Chapter 5.4.3.2, "Display Lines", on page 213 and Chap-
ter 5.4.3.4, "Working with Lines", on page 215.
Common Analysis Functions