Measurements and Results
R&S
®
FSW
259User Manual 1173.9411.02 ─ 43
Tx Bandwidth ← Channel Power Settings
Defines the bandwidth used for measuring the channel power, with:
Minimum span ≤ "Tx Bandwidth" ≤ of reference range
Remote command:
[SENSe:]ESPectrum<sb>:BWID on page 936
RRC Filter State ← Channel Power Settings
Activates or deactivates the use of an RRC filter.
Remote command:
[SENSe:]ESPectrum<sb>:FILTer[:RRC][:STATe] on page 936
Alpha: ← Channel Power Settings
Sets the alpha value of the RRC filter (if activated).
Remote command:
[SENSe:]ESPectrum<sb>:FILTer[:RRC]:ALPHa on page 936
7.6.5.4 Power Classes
Access: "Overview" > "Select Measurement" > "Spectrum Emission Mask" > "Power
Classes"
You can configure power classes which you can then assign to sweep list ranges. For
details, see "Power classes" on page 241.
Used Power Classes:..................................................................................................260
PMin/ PMax.................................................................................................................260
Sweep List...................................................................................................................260
Adding or Removing a Power Class........................................................................... 260
Spectrum Emission Mask (SEM) Measurement