Network and Remote Operation
R&S
®
FSW
815User Manual 1173.9411.02 ─ 43
2. On the R&S FSW, a user logs on.
The connection to the controller is terminated as a result. A message is displayed
on the controller display indicating that another user has assumed control of the
instrument.
Restoring the connection to the R&S FSW
Follow the instructions above for setting up a connection to the R&S FSW. If the con-
nection is terminated and then restored, the R&S FSW remains in the same state.
13.6.7.4 How to Shut Down the R&S FSW via Remote Operation
1. Select the R&S FSW softfrontpanel and close the application with the key combi-
nation [ALT] + [F4].
2. Select the desktop and press the key combination [ALT] + [F4].
A safety query is displayed to warn you that the instrument cannot be reactivated
via remote operation and asks you whether you want to continue the shutdown
process.
3. Respond to the safety query with "Yes".
The connection with the controller is terminated and the R&S FSW is shut down.
13.6.8 How to Start a Remote Control Session from a PC
When you switch on the R&S FSW, it is always in manual operation state ("local" state)
and can be operated via the front panel.
To start remote control
1. Send an addressed command (GTR - Go to Remote) from a controller to the instru-
ment.
The instrument is switched to remote control ("remote" state). Operation via the
front panel is disabled. Only the "Local" softkey is displayed to return to manual
operation. The instrument remains in the remote state until it is reset to the manual
state via the instrument or via remote control interfaces. Switching from manual
operation to remote control and vice versa does not affect the other instrument set-
tings.
2. During program execution, send the SYSTem:DISPlay:UPDate ON command to
activate the display of results (see SYSTem:DISPlay:UPDate on page 1297).
The changes in the device settings and the recorded measurement values are dis-
played on the instrument screen.
3. To obtain optimum performance during remote control, send the
SYSTem:DISPlay:UPDate OFF command to hide the display of results and dia-
grams again (default setting in remote control).
How to Set Up a Network and Remote Control

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S FSW Series and is the answer not in the manual?

R&S FSW Series Specifications

General IconGeneral
BrandR&S
ModelFSW Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals