Remote Commands
R&S
®
FSW
900User Manual 1173.9411.02 ─ 43
//Initiates a new measurement and waits until the sweep has finished.
// Now turn off the carrier signal and repeat the measurement:
INIT;*WAI
//Initiates a new measurement and waits until the sweep has finished.
//---------------Retrieving Results-------------
CALC:MARK:FUNC:POW:RES? CN
//Returns the carrier-to-noise ratio.
14.5.5 Measuring the Occupied Bandwidth
All remote control commands specific to occupied bandwidth measurements are
described here.
● Configuring the Measurement...............................................................................900
● Programming Example: OBW Measurement........................................................901
14.5.5.1 Configuring the Measurement
The following commands configure measurements of the occupied bandwidth.
Useful commands for occupied bandwidth measurements described elsewhere
Configuring the channel:
●
[SENSe:]POWer:ACHannel:BANDwidth[:CHANnel<ch>]
●
[SENSe:]POWer:ACHannel:PRESet
●
[SENSe:]POWer:ACHannel:PRESet:RLEVel
Defining search limits:
●
CALCulate<n>:MARKer<m>:X:SLIMits[:STATe] on page 1159
●
CALCulate<n>:MARKer<m>:X:SLIMits:LEFT on page 1160
●
CALCulate<n>:MARKer<m>:X:SLIMits:RIGHt on page 1160
Performing the measurement:
●
CALCulate<n>:MARKer<m>:FUNCtion:POWer<sb>:SELect on page 839
●
CALCulate<n>:MARKer<m>:FUNCtion:POWer<sb>[:STATe] on page 840
Retrieving results:
●
CALCulate<n>:MARKer<m>:FUNCtion:POWer<sb>:RESult? on page 837
Remote commands exclusive to occupied bandwidth measurements:
[SENSe:]POWer:BWIDth................................................................................................ 901
[SENSe:]POWer:BANDwidth...........................................................................................901
Configuring and Performing Measurements